Accredited
calibration services:

From -196oC
to 1000oC ASTM thermometers, digital thermometers, PRTs,
thermocouples, thermistors

Specific Gravity
hydrometers. API hydrometers, Baume hydrometers,
Kg/M3 (density) hydrometers, Brix hydrometers, Proof hydrometers

ASTM Class 1 and
OIML E-2 and lesser specification stainless steel and brass laboratory weights.
New calibrated weights and re-calibration of weights you currently have.

Thermo-hygrometers,
chart recorders, humidity sensors, data-loggers

Burets, pipets,
volumetric flasks, graduated cylinders, volumetric glassware

Testing and
certification that an instrument complies with specified accuracy
requirements...







| |
ERTCO
SPECIAL APPLICATION THERMOMETERS
Over the years, ERTCO has designed thermometers for
customers with needs that were not filled by instruments in their normal product line. The
following listings are among those that were developed, have gained popularity, and are
now used in many special applications. They include a variety of ranges, subdivisions,
immersions, and lengths. All are accurate to within NIST tolerances.
Any of these thermometers may be furnished with ICL's NIST Traceable
calibration report upon request.

|
Catalog No. |
Temp range |
Divisions |
Length, mm |
Immersion, mm |
Special Features |
Application |
Teflonź sheath |
List price |
| 711 |
20 to 100șC |
1.0șC |
305 |
76 |
1,2 |
Incubator, Water Bath |
No |
54.00 |
| 711-C
|
Above thermometer
with ICLs NIST Traceable calibration report @ 25, 60, 100C |
204.00 |
| 711-SC |
20 to 100șC |
1.0șC |
305 |
76 |
1,2 |
Incubator, Water Bath |
Yes |
65.00 |
| 711-SC-C
|
Above thermometer
with ICLs NIST Traceable calibration report @ 25, 60, 100C |
204.00 |
|
Catalog No. |
Temp range |
Divisions |
Length, mm |
Immersion, mm |
Special Features |
Application |
Teflonź sheath |
List price |
|
641 |
0 to 80șC |
1.0șC |
250 |
100 |
|
Incubator,
Water Bath |
No |
39.90
|
|
641-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 40, 80C |
189.90 |
|
641-SC |
0 to 80șC |
1.0șC |
250 |
100 |
|
Incubator, Water Bath |
Yes |
48.40 |
|
641-SC-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 40, 80C |
198.40 |
|
637-1 |
0 to 50șC |
0.5șC |
305 |
150 |
1 |
Incubator, Water Bath |
No |
38.90 |
|
637-1-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 25, 50C |
188.90 |
|
637-1SC |
0 to 50șC |
0.5șC |
305 |
150 |
1 |
Incubator, Water Bath |
Yes |
48.40 |
|
637-1SC-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 25, 50C |
198.40 |
|
639-1 |
0 to 70șC |
1.0șC |
330 |
150 |
1 |
Incubator, Water Bath |
No |
47.50 |
|
639-1-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 35, 70C |
197.50 |
|
639-1SC |
0 to 70șC |
1.0șC |
330 |
150 |
1 |
Incubator, Water Bath |
Yes |
58.00 |
|
639-1SC-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 35, 70C |
208.00 |
|
713 |
34.5 to 46șC |
0.1șC |
237 |
76 |
2 |
Coliform Incubator |
No |
83.00 |
|
713-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 35, 40, 45C |
233.00 |
|
Catalog No. |
Temp range |
Divisions |
Length, mm |
Immersion, mm |
Special Features |
Application |
Teflonź sheath |
List price |
| 713-SC |
34.5 to 46șC |
0.1șC |
237 |
76 |
2 |
Coliform Incubator |
Yes |
92.00 |
|
713-SC-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 35, 40, 45C |
242.00 |
|
715 |
25 to 57șC |
0.5șC |
175 |
35 |
2 |
Block Heater, Water Bath |
No |
53.00 |
| 715-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 26, 37, 55C |
203.00 |
|
715-SC |
25 to 57șC |
0.5șC |
175 |
35 |
2 |
Block Heater, Water Bath |
Yes |
62.00 |
| 715-SC-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 26, 37, 55C |
212.00 |
|
647 |
0 to 100șC |
1.0șC |
225 |
35 |
|
Block Heater, Water Bath |
No |
52.00 |
| 647-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 50, 100C |
186.80 |
|
647-SC |
0 to 100șC |
1.0șC |
225 |
35 |
|
Block Heater, Water Bath |
Yes |
62.00 |
| 647-SC-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 50, 100C |
212.00 |
645
|
0 to 50șC |
1.0șC |
100 |
12 |
|
Short Immersion Bath |
No |
53.00 |
| 645-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 25, 50C |
203.00 |
645-SC
|
0 to 50șC |
1.0șC |
100 |
12 |
|
Short Immersion Bath |
Yes |
62.00 |
| 645-SC-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 25, 50C |
212.00 |
|
717 |
5 to 20șC |
1.0șC |
152 |
Total |
2 |
Blood Bank , Refrigerator |
No |
31.10 |
| 717-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 6, 12 20C |
181.10 |
| 717-SC |
5 to 20șC |
1.0șC |
152 |
Total |
2 |
Blood Bank , Refrigerator |
Yes |
40.90 |
| 717-SC-C |
Above thermometer with ICLs NIST Traceable calibration report @ 6, 12, 20C |
190.90 |
|
Catalog No. |
Temp range |
Divisions |
Length, mm |
Immersion, mm |
Special Features |
Application |
Teflonź sheath |
List price |
2457
|
25-37-56șC |
0.5șC |
240 |
76 |
2 |
Incubator, Water Bath |
No |
40.50 |
| 2457-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 25, 37, 56C |
190.50 |
|
2457-SC |
25-37-56șC |
0.5șC |
240 |
76 |
2 |
Incubator, Water Bath |
Yes |
51.00 |
| 2457-SC-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 25, 37, 56C |
201.00 |
|
80135 |
80 to 135șC |
1.0șC |
200 |
Total |
No |
Autoclave, Maximum
Regist. |
No |
64.00 |
| 80135-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 100, 121C |
177.00 |
|
80135-SC |
80 to 135șC |
1.0șC |
200 |
Total |
Autoclave, Maximum
Regist. |
Yes |
No |
74.00 |
| 80135-SC-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 100, 121C |
95.32 |
|
629 |
0 to 300șC |
1.0șC |
405 |
125 |
1 |
Ovens, oil Baths |
No |
47.60 |
| 629-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 100, 200,
300C |
286.60 |
|
631 |
0 to 300șC |
1.0șC |
455 |
150 |
1 |
Ovens, oil Baths |
No |
57.00 |
| 631-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 100, 200,
300C |
296.00 |
| 633 |
0 to 300șC |
1.0șC |
610 |
305 |
1 |
Ovens |
No |
76.00 |
| 633-C |
bove thermometer with ICLs NIST Traceable
calibration report @ 0, 100, 200,
300C |
302.60 |
|
635 |
0 to 200șC |
1.0șC |
610 |
305 |
1 |
Ovens |
No |
76.00 |
| 635-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 100, 200C |
239.00 |
|
635-SC |
0 to 200șC |
1.0șC |
610 |
305 |
1 |
Ovens |
Yes |
85.00 |
| 635-SC-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 100, 200C |
248.00 |
|
Catalog No. |
Temp range |
Divisions |
Length, mm |
Immersion, mm |
Special Features |
Application |
Teflonź sheath |
List price |
|
637 |
0 to 200șC |
1.0șC |
280 |
76 |
1 |
Ovens,
oil baths |
No |
46.90 |
|
637-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 100, 200C |
209.90 |
|
637-SC |
0 to 200șC |
1.0șC |
280 |
76 |
1 |
Ovens, oil Baths |
Yes |
57.00 |
|
637-SC-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 100, 200C |
220.00 |
|
639 |
0 to 200șC |
1.0șC |
405 |
125 |
1 |
Ovens, oil Baths |
No |
52.00` |
|
639-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 100, 200C |
215.00 |
|
639-SC |
0 to 200șC |
1.0șC |
405 |
125 |
1 |
Ovens, oil Baths |
Yes |
61.00 |
|
639-SC-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 100, 200C |
224.00 |
|
631350 |
0 to 350șC |
1.0șC |
455 |
150 |
1 |
Ovens |
No |
76.00 |
| 631350-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 0, 100, 200,
300C |
315.00 |
|
24130 |
24 to 130șC |
2.0șC |
135 |
Total |
|
Vacuum
ovens |
No |
43.80 |
|
24130-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 25, 75, 125C |
206.80 |
|
24130-SC |
24 to 130șC |
2.0șC |
135 |
Total |
|
Vacuum ovens |
Yes |
53.00 |
|
24130-SC-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 25, 75,
125C |
216.00 |
|
7200 |
35 to 200șC |
1.0șC |
180 |
Total |
|
Vacuum ovens |
No |
44.70 |
| 7200-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 40, 120, 200C |
233.70 |
|
7200-SC |
35 to 200șC |
1.0șC |
180 |
Total |
|
Vacuum ovens |
Yes |
55.00 |
|
7200-SC-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 40, 120,
200C |
241.00 |
|
934 |
24 to 38șC |
0.05șC |
300 |
95 |
|
Enzymology |
No |
91.00 |
|
934-C |
Above thermometer with ICLs NIST Traceable
calibration report @ 25, 30, 37C |
241.00 |
SPECIAL FEATURES:
1. Immersion enlargement on thermometer stem.
2. Arrows on scale indicating critical temperature.
ERTCO is a registered trademark of EverReady Thermometer Company, Inc.
Teflonź is a registered trademark of DuPont |