Accredited
calibration services:

From -196oC
to 1000oC ASTM thermometers, digital thermometers, PRTs,
thermocouples, thermistors

Specific Gravity
hydrometers. API hydrometers, Baume hydrometers,
Kg/M3 (density) hydrometers, Brix hydrometers, Proof hydrometers

ASTM Class 1 and
OIML E-2 and lesser specification stainless steel and brass laboratory weights.
New calibrated weights and re-calibration of weights you currently have.

Thermo-hygrometers,
chart recorders, humidity sensors, data-loggers

Burets, pipets,
volumetric flasks, graduated cylinders, volumetric glassware

Testing and
certification that an instrument complies with specified accuracy
requirements...







| |

ENVIRONMENTAL CHAMBER
THERMOMETERS
NIST TRACEABLE THERMOMETERS FOR:
FREEZERS - REFRIGERATORS - INCUBATORS - OVENS
- Specifically
designed to comply with CLIA and EPA specifications
- Precision mercury in glass or
red spirit filled thermometers
- Graduated in 0.5º Divisions ( 210-008 &
210-012 are graduated in 1 deg divisions; 210-010 is graduated in 0.1 deg
divisions)
- TEFLON® ENCAPSULATED for safety, breakage
resistance and to contain the
mercury and glass in the event of a breakage
- NIST Traceable VERIFIED (see Certificate of
Accuracy below)
- Mounted in polypropylene bottle, filled with
mineral oil (pharmaceutical grade) or sand (oven ranges), to prevent changes
of the reading when chamber is opened to read the thermometer
®Teflon is a registered trademark of DuPont
CERTIFICATE OF
ACCURACY
for Thermometer Cat. No. 210-002
Range -5/20C
This thermometer, serial number ABC123, was compared against our
transfer standard thermometers and was found to be accurate within +/-
0.5oC at the test temperatures of 0o
& 4oC.
This calibration was performed in accordance with the procedures
outlined in ICL Procedure 01, which is based upon ASTM E-77.
This pronouncement of compliance to this accuracy tolerance was made by
resolving the indication of this thermometer (under magnification) to
1/10 of the smallest scale division, and determining that the value thus
determined resided within the stated interval. The measurement
uncertainty attributable to this observation, +/- 0.06oC,
is expressed at 2 sigma (k=2), to state the uncertainty at a 95%
confidence level.
The NIST primary reference standard thermometer referenced for this
calibration is a NIST calibrated SPRT, Rosemount model 162CE,
serial no. 5058, calibrated by NIST on May 15, 2006.
The indications of this thermometer are traceable to NIST
through an unbroken chain of comparisons. Each step of the chain is
fully documented, and measurement uncertainties have been calculated at
each step.
Date report issued: 06-12-2006
ICL CALIBRATION LABORATORIES, INC.
1501 Decker Avenue Suite 118 Stuart, FL 34994
Tel: 772 286 7710 Fax: 772 286 8737 Internet: www.icllabs.com email:
sales@icllabs.com
|
| Ordering Information: |
| Cat. No. |
Temperature Range |
Application |
Filling Liquid |
Div |
Verified at: |
Price |
| 210-000 |
-30 to +1ºC |
Freezer |
Mercury |
0.5º |
-20, 0ºC |
56.65 |
|
210-000-RL |
-30 to +1ºC |
Freezer |
Red
Spirit |
0.5º |
-20, 0ºC |
56.65 |
| 210-002 |
-5 to +20ºC |
Refrigerator |
Mercury |
0.5º |
0, 4ºC |
56.65 |
|
210-002-RL |
-5 to +20ºC |
Refrigerator |
Red
Spirit |
0.5º |
0, 4ºC |
56.65 |
| 210-003 |
18 to 50ºC |
Incubators |
Mercury |
0.5º |
20, 35, 50ºC |
56.65 |
|
210-003-RL |
18 to 50ºC |
Incubators |
Red
Spirit |
0.5º |
20, 35, 50ºC |
56.65 |
| 210-008 |
-5 to 130ºC |
Ovens |
Mercury |
1.0º |
0, 80, 110ºC |
63.75 |
|
210-008-RL |
-5 to 130ºC |
Ovens |
Red
Spirit |
1.0º |
0, 80, 110ºC |
63.75 |
| 210-010 |
-0.6 to 10.4ºC |
Refrigerator |
Mercury |
0.1º |
0, 5, 10ºC |
123.60 |
| 210-012 |
-5 to 205C |
Ovens |
Mercury |
1.0º |
0,
100, 200ºC |
96.82 |
ALL ITEMS
NORMALLY IN STOCK FOR IMMEDIATE SHIPMENT!
Back to Thermometer Index |
|
| |
|