Accredited calibration services: From -196oC to 1000oC ASTM thermometers, digital thermometers, PRTs, thermocouples, thermistors Specific Gravity
hydrometers. API hydrometers, Baume hydrometers, ASTM Class 1 and OIML E-2 and lesser specification stainless steel and brass laboratory weights. New calibrated weights and re-calibration of weights you currently have. Thermo-hygrometers, chart recorders, humidity sensors, data-loggers Burets, pipets, volumetric flasks, graduated cylinders, volumetric glassware |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ASTM No. | Cat No | Application | Range | Div | Length | Immersion | List price |
|---|---|---|---|---|---|---|---|
| 81F | 10081F | Viscosity, Saybolt | 445 to 465oF | 0.5o | 275mm | total | 65.00 |
| 10081F-C | ASTM 81F calibrated @ ASTM specified test points of 450, 460oF | 221.00 | |||||
| ASTM No. | Cat No | Application | Range | Div | Length | Immersion | List price |
| 82C | 10082C | Fuel Rating, Engine | -15 to 105oC | 1o | 165mm | 30mm | 46.25 |
| 10082C-C | ASTM 82C calibrated @ ASTM specified test points of 0, 50, 100oC | 202.25 | |||||
| 82F | 10082F | Fuel Rating, Engine | 0 to 220oF | 2o | 165mm | 30mm | 46.25 |
| 10082F-C | ASTM 82F calibrated @ ASTM specified test points of 32, 100, 200oF | 202.25 | |||||
| ASTM No. | Cat No | Application | Range | Div | Length | Immersion | List price |
| 83C | 10083C | Fuel Rating, Air | 15 to 70oC | 1o | 174mm | 40mm | 46.25 |
| 10083C-C | ASTM 83C calibrated @ ASTM specified test points of 25, 70oC | 150.25 | |||||
| 83F | 10083F | Fuel Rating, Air | 60 to 160oF | 1o | 174mm | 40mm | 46.25 |
| 10083F-C | ASTM 83F calibrated @ ASTM specified test points of 85, 135oF | 150.25 | |||||
| ASTM No. | Cat No | Application | Range | Div | Length | Immersion | List price |
| 84C | 10084C | Fuel Rating, Orifice | 25 to 80oC | 1o | 387mm | 249mm | 46.25 |
| 10084C-C | ASTM 84C calibrated @ ASTM specified test points of 30, 80oC | 150.25 | |||||
| 84F | 10084F | Fuel Rating, Orifice | 75 to 175oF | 1o | 387mm | 249mm | 46.25 |
| 10084F-C | ASTM 84F calibrated @ ASTM specified test points of 100, 150oF | 150.25 | |||||
| ASTM No. | Cat No | Application | Range | Div | Length | Immersion | List price |
| 85C | 10085C | Fuel Rating, Surge | 40 to 150oC | 1o | 314mm | 181mm | 46.25 |
| 10085C-C | ASTM 85C calibrated @ ASTM specified test points of 50, 150oC | 163.25 | |||||
| 85F | 10085F | Fuel Rating, Surge | 100 to 300oF | 2o | 314mm | 181mm | 46.25 |
| 10085F-C | ASTM 85F calibrated @ ASTM specified test points of 150, 250oF | 163.25 | |||||
| ASTM No. | Cat No | Application | Range | Div | Length | Immersion | List price |
| 86C | 10086C | Fuel Rating, Mix | 95 to 175oC | 1o | 170mm | 35mm | 52.50 |
| 10086C-C | ASTM 86C calibrated @ ASTM specified test points of 100, 175oC | 169.50 | |||||
| 86F | 10086F | Fuel Rating, Mix | 200 to 350oF | 2o | 170mm | 35mm | 52.50 |
| 10086F-C | ASTM 86F calibrated @ ASTM specified test points of 225, 325oF |
182.50 |
|||||
| ASTM No. | Cat No | Application | Range | Div | Length | Immersion | List price |
| 87C | 10087C | Fuel Rating, Coolant | 150 to 205oC | 1o | 175mm | 40mm | 60.00 |
| 10087C-C | ASTM 87C calibrated @ ASTM specified test points of 160, 200oC | 190.00 | |||||
| 87F | 10087F | Fuel Rating, Coolant | 300 to 400oF | 1o | 175mm | 40mm | 60.00 |
| 10087F-C | ASTM 87F calibrated @ ASTM specified test points of 300, 400oF | 203.00 | |||||
| ASTM No. | Cat No | Application | Range | Div | Length | Immersion | List price |
| 88C | 10088C | Vegetable Oil Flash | 10 to 200oC | 1o | 287mm | 57mm | 72.50 |
| 10088C-C | ASTM 88C calibrated @ ASTM specified test points of 40, 100, 150, 200oC | 306.50 | |||||
| 88F | 10088F | Vegetable Oil Flash | 50 to 392oF | 2o | 287mm | 57mm | 72.50 |
| 10088F-C | ASTM 88F calibrated @ ASTM specified test points of 110, 212, 300, 392oF | 306.50 | |||||
| ASTM No. | Cat No | Application | Range | Div | Length | Immersion | List price |
| 89C | 10089C | Solidification Point | -20 to +10oC | 0.1o | 370mm | 76mm | 70.00 |
| 10089C-C | ASTM 89C calibrated @ ASTM specified test points of -20, -10, 0, 10oC | 324.00 | |||||
| 90C | 10090C | Solidification Point | 0 to 30oC | 0.1o | 370mm | 76mm | 60.00 |
| 10090C-C | ASTM 90C calibrated @ ASTM specified test points of 0, 10, 20, 30oC | 268.00 | |||||
| 91C | 10091C | Solidification Point | 20 to 50oC | 0.1o | 370mm | 76mm | 60.00 |
| 10091C-C | ASTM 91C calibrated @ ASTM specified test points of 20, 30, 40, 50oC | 268.00 | |||||
| 92C | 10092C | Solidification Point | 40 to 70oC | 0.1o | 370mm | 76mm | 63.75 |
| ` | 10092C-C | ASTM 92C calibrated @ ASTM specified test points of 40, 50, 60, 70oC | 271.75 | ||||
| ASTM No. | Cat No | Application | Range | Div | Length | Immersion | List price |
| 93C | 10093C | Solidification Point | 60 to 90oC | 0.1o | 370mm | 76mm | 70.00 |
| 10093C-C | ASTM 93C calibrated @ ASTM specified test points of 60, 70, 80, 90oC | 278.00 | |||||
| 94C | 10094C | Solidification Point | 80 to 110oC | 0.1o | 370mm | 76mm | 70.00 |
| 10094C-C | ASTM 94C calibrated @ ASTM specified test points of 80, 90, 100, 110oC | 291.00 | |||||
| 95C | 10095C | Solidification Point | 100 to 130oC | 0.1o | 370mm | 76mm | 75.00 |
| 10095C-C | ASTM 95C calibrated @ ASTM specified test points of 100, 110, 120, 130oC | 322.00 | |||||
| 96C | 10096C | Solidification Point | 120 to 150oC | 0.1o | 370mm | 76mm | 75.00 |
| 10096C-C | ASTM 96C calibrated @ ASTM specified test points of 120, 130, 140, 150oC | 335.00 | |||||
| ASTM No. | Cat No | Application | Range | Div | Length | Immersion | List price |
| 97C | 10097C | Tank, Refill | -18 to 49oC | 0.5o | 300mm | total | 45.00 |
| 10097C-C | ASTM 97C calibrated @ ASTM specified test points of -15, 0, 20, 45oC | 276.00 | |||||
| 97F | 10097F | Tank, Refill | 0 to 120oF | 1o | 300mm | total | 45.00 |
| 10097F-C | ASTM 97F calibrated @ ASTM specified test points of 0, 32, 70, 110oF | 276.00 | |||||