|
Accredited
calibration services:

From -196oC
to 1000oC ASTM thermometers, digital thermometers, PRTs,
thermocouples, thermistors

Specific Gravity
hydrometers. API hydrometers, Baume hydrometers,
Kg/M3 (density) hydrometers, Brix hydrometers, Proof hydrometers

ASTM Class 1 and
OIML E-2 and lesser specification stainless steel and brass laboratory weights.
New calibrated weights and re-calibration of weights you currently have.

Thermo-hygrometers,
chart recorders, humidity sensors, data-loggers

Burets, pipets,
volumetric flasks, graduated cylinders, volumetric glassware

Testing and
certification that an instrument complies with specified accuracy
requirements...







| |
DIGITAL LABORATORY THERMOMETERS
|
 |
EUTECHNICS HIGH PRECISION DIGITAL THERMOMETERS The ERTCO-Eutechnics High
Precision Digital Thermometer is a multi-purpose, economical, ultra-high
accurate, hand held thermometer. The probes are manufactured from the highest
grade thermistor wire available and are comparable to digital instruments
costing three times the price. A model with RS-232 option is available to
maintain permanent records. An AC adapter is also available for continual 110v
use.
-
FURNISHED WITH 7”
STAINLESS STEEL PROBE OR MICRO PROBE (1” X 0.03” DIA)
-
ULTRA-HIGH ACCURACY
0 to 70° C. : ± 0.025° C, 0 to 100° C. : ±
0.030° C, -20° C to 130° C. : ± 0.050° C
-
HIGH RESOLUTION (0.01oC)
-
RANGE -20 TO 130oC
and -30 TO 260oF (Selectable from
panel)
-
AUTO SHUT-OFF (SELECTABLE
AUTO/MANUAL)
-
RUGGED FIELD-TESTED ABS
CARRYING/STORAGE CASE STANDARD
-
LOW BATTERY INDICATOR
-
OVER/UNDER RANGE INDICATOR
|
| ICL
Catalog Number: |
Description |
|
139000-44 |
Thermometer with Micro Probe
|
|
139000-44-C |
Thermometer with Micro Probe and ICL’s ISO/IEC 17025
calibration report at 8 test temperatures: -20o, 0oC, 4oC,
25oC, 37oC, 56oC, 105oC, and
121oC |
|
139000-45 |
Thermometer with General Purpose Probe |
|
139000-45-C |
Thermometer with Micro Probe and ICL’s ISO/IEC 17025
calibration report at 8 test temperatures: -20o, 0oC, 4oC,
25oC, 37oC, 56oC, 105oC, and
121oC |
|
139000-44RS |
Thermometer with Micro Probe and RS-232 Option |
|
139000-45RS |
Thermometer with Standard Probe and RS-232 Option |
ACCESSORIES
| Catalog
No. |
Description |
| 139000-50 |
AC Adapter 110/220V
$ 63.50 |
|
 |
HART
SCIENTIFIC DIGITAL THERMOMETER 1502A
HART’s
high precision 1502A PRT digital thermometer readout is designed with metrology
laboratory and industrial laboratory applications in mind.
|
|
Temperature range: |
|
–200°C to
962°C (–328°F to 1764°F) |
|
|
|
Resolution: |
0.001o |
|
Accuracy: |
±0.004°C at –100°C
±0.006°C at 0°C
±0.009°C at 100°C
±0.012°C at 200°C
±0.018°C at 400°C
±0.024°C at 600°C |
|
Display: |
8
digit alphanumeric LED |
|
Readout: |
oC, oF, Kelvin or Ohms; IPTS-68 or ITS-90
|
|
Probe connection: |
5
pin DIN, one spare connector included with meter |
|
Probe: |
4
wire 100 ohm PRT (not included) |
|
Computer interface: |
RS-232, 300 to 2400 baud |
|
Voltage: |
115 VAC, 60Hz |
|
Shipping weight: |
4
Ibs (1.8 kg) |
| Coefficient conversion: |
IPTS-68, ITS-90, or CVD |
PROBE
SIZES AND SPECIFICATIONS:
| Cat.
No. |
5613 |
5614 |
|
Size |
6" L
x 3/16" Diameter |
12" L
x 1/4" Diameter |
| Range |
-196 to 300oC |
-196 to 420oC |
|
Resistance at 0oC |
Nominal
100 ohm |
Nominal
100 ohm |
| Temp
Coefficient |
392 |
392 |
|
Resistance Stability |
+/-0.01oC/yr |
+/-0.01oC/yr |
|
Accuracy |
|
±0.018°C at
–196°C
±0.018°C at 0°C
±0.019°C at 200°C
±0.023°C at 300°C |
|
|
±0.018°C at –196°C
±0.018°C at 0°C
±0.019°C at 200°C
±0.023°C at 420°C |
|
The Model 1502A Tweener features
accuracy up to ±0.006°C. In addition, it reads both 100-ohm and 25-ohm probes,
has a resolution of 0.001°C across its entire range and is the smallest unit in
the industry. It also has an optional battery pack for completely portable
operation.
Each Tweener is programmable to
match any probe’s constants for maximum linearity and accuracy. All probe
constants and coefficients are programmed through simple, front-panel
keystrokes. Temperature is displayed in °C, °F, K, or resistance in ohms.
The 1502A accurately measures the
resistance of the probe and then converts the resistance to a temperature value
using its built-in algorithms.
For convenience, the 1502A reads the
common industrial grade IEC-751 or “385” ALPHA RTD without any programming.
Enter the actual R0 and ALPHA of the individual probe for increased accuracy.
For maximum accuracy, use the ITS-90 formulas. The Tweener accepts the subranges
4 and 6 through 11.
ITS-90 formulas reside in its
firmware. If your probe has been calibrated for any of the subranges of the
ITS-90, you simply enter the coefficients directly into the Tweener.
Each thermometer comes complete with
an RS-232 interface for automation of temperature data collection, calibrations,
or process control functions. An IEEE-488 interface is available as an option.
The 1502A is calibrated digitally
using the front-panel buttons. You never have to open the box to calibrate it.
This calibration protocol further reduces the cost of the 1502A. It goes where
you go and works the way you want it to.
Software
With Hart's Model 9934 LogWare
software, the Tweener may be used for real-time data acquisition. Collect data
and analyze it graphically or statistically.
Battery Option
If you want freedom from AC power in
the field or on the plant floor, order Model 2502 and we’ll install a DC power
board in your Tweener. Then you can connect your own 12-volt DC power or order
Hart’s 9313 Battery Pack. The battery gives you three to eight hours between
charges. It includes a charger and a nylon pouch with a belt clip. |
|
Catalog No. |
Description |
| 1502A |
Readout (without probe) |
|
5615 |
12”
PRT Sensor |
| TCAL |
ISO/IEC 17025, NIST Traceable report of calibration @ test
points –196, -40, 0, 200 & 400°C |
Accessories
|
EH2507 |
Printer, 20 column, with serial cable, AC adaptor/charger
and NICAD batteries |
|
IEEE-488 |
IEEE Computer Interface |
|
EH2509 |
Logging and data acquisition software |
|
 |
Hart Scientific Handheld
Standards
Thermometers
Models
1521 and 1522
|
| The Models 1521 and 1522
are the first standards thermometers to fit into a battery-powered handheld
package. They’re as accurate as ±0.005°C! You’ll only find this level of
accuracy in large desktop units that cost three times more. It’s no wonder we
call the 1521 the Little Lord Kelvin of thermometry. Fitting easily into your
hand and weighing only 1 pound (0.4 kg), these thermometers can go anywhere.
And when they get there, you can have total confidence in the accuracy of your
measurements. The 1522 has the power of a full data logger, with memory to hold
10,000 readings.
The 1521 and 1522 read
both PT-25 and Pt-100 RTDs as well as thermistors.
PRTs and RTDs, with their
wide temperature ranges and stabilities, have long been favored as temperature
standards. From –200°C to 100°C, the 1521 reads PRTs accurately to ±0.025°C.
Even at 800°C these are high-precision readouts, accurate to ±0.1°C.
Ultra-stable thermistors
offer excellent stability and even greater accuracies over a more narrow
range—typically from about –10°C to 110°C. At temperatures below 50°C, these
Handheld Thermometers read thermistors to ±0.005°C. Accuracy at 100°C is
±0.02°C.
While a small number of
handheld thermometers on the market offer 0.01° resolution, they fail to provide
the accuracy necessary for the last digit to be meaningful. Hart’s Handheld
Thermometers let you select resolution from 0.1° to 0.001° and offer the
accuracy to support even 0.001° resolution.
Of course, the 1521 and 1522
let you match the exact resistance-versus-temperature characteristics of an
individually calibrated probe. This is true standards thermometry. Hart’s
Handheld Thermometers read ITS-90, Callendar-Van Dusen, or Steinhart-Hart
coefficients for maximum system accuracy. These are real algorithms, not
approximating conversion methods or electronic look-up tables. If you want to
use common industrial curves, RTDs can be read using the common DIN 43760 (IEC
751) curve and thermistors can be read using the YSI 400 curve. |
|
|
Catalog No. |
Description |
| 1521 |
Thermometer, Handheld, 1 Channel
(without probe) |
| 1522 |
Thermometer, Handheld, 1 Chan Data Logger
(without probe) |
|
5614 |
12”
PRT Sensor |
|
5613 |
6”
PRT Sensor |
| TCAL |
ISO/IEC 17025, NIST Traceable report of calibration @ test
points –196, -40, 0, 200 & 400°C |
|
 
|
TM 99A THERMISTOR
DIGITAL THERMOMETER
From Cooper Instrument Corporation
-
Temperature ranges: -40/300ºF or –40/150ºC, user selectable from keypad
Note: recommended range of use -20/120ºC
-
Display resolution: 0.1ºF
or C
-
Battery: 9v alkaline
(regular transistor battery)
-
Sensor:
thermistor element, enclosed in stainless steel sheath
-
Display: Large
illuminated LCD, with backlight function for low light conditions.
-
Min/Max memory
-
Battery eliminator jack
for continuous operation. Requires power supply No. 9313 (optional)
-
Case: Rugged plastic
carrying / storage case included (see smaller photo below)
|
| ICL
Catalog Number: |
Description |
|
TM-99A |
Thermometer with General Purpose Probe & carrying case |
|
TM-99A-C |
Thermometer with General Purpose Probe & carrying case. Supplied with
NIST traceable, ISO/IEC 17025 accredited report of calibration. |
|
 |
TL-1A Digital
Laboratory Thermometer
The TL-1 emulates glass thermometer simplicity and
reliability with the ease of a 2 decimal place digital display. Excellent
accuracy and a wide temperature range. Replaces a set of 9 lab grade mercury
thermometers. One year warranty.
See
Specification Sheet
New Features:
-
Temperature Logging &
Averaging
-
Temperature
trend and stabilization indicators
-
Automatically
shuts off after twenty minutes
-
Intrinsically Safe
Certification
|
| ICL
Catalog Number: |
Description |
|
TL-1A |
TL-1A
digital laboratory thermometer |
|
TL-1A-C |
TL-1A digital laboratory thermometer.
Supplied with NIST traceable, ISO/IEC 17025 accredited report of
calibration. |
|
 |
TL-1W Digital Thermometer
The TL-1W is a modified field version of our
successful TL-1A thermometer. It features a rugged frame for reinforcement
and is designed for continuous operation but can be easily powered off if
desired. The TL-1W thermometer is intended to be used anywhere a precision
glass stem thermometer or other type thermometer may be used. The TL-1W
incorporates glass thermometer simplicity and reliability with the ease of a
digital
display.
See Specification Sheet New Features:
-
Temperature Logging &
Averaging
-
Temperature
trend and stabilization indicators
-
Automatically
shuts off after twenty minutes
-
Intrinsically Safe
Certification
|
| ICL
Catalog Number: |
Description |
|
TL-1W |
TL-1W
digital laboratory thermometer |
|
TL-1W-C |
TL-1W digital laboratory thermometer.
Supplied with NIST traceable, ISO/IEC 17025 accredited report of
calibration. |
|

|
HANNA INSTRUMENTS
MICROPROCESSOR K – TYPE
THERMOCOUPLE THERMOMETER
For verification of ovens and
muffle furnaces
This thermometer allows
temperature measurement using interchangeable K-type thermocouple probes. The
thermometer uses a microprocessor to linearize the response of the thermocouple
in order to achieve high degree accuracy and
resolution. It also permits accurate compensation for drifts in the measurement
circuit and the reference junction.
Standard feature include:
* Display of the temperature in
Celsius or Fahrenheit
* Reading hold
* Low battery detection
These functions are easily
accessible through the keypad. Self-explanatory symbols are used to remind the
user of the operating mode or condition.
Specifications:
Range: -200.0 to 999.9oC
(-300.0 to 999.9oF)
Resolution: 0.1oC
(-200 to 999.5oC)
Accuracy: +/- 2.2oC
or 75% of reading
Battery life: 100 hours – 4 X
1.5V AAA
Environment: 0 to 50oC
(32 to 122oF) 100%RH
Dimensions: 196 X 80 X 60 mm
(7.7 X 3.1 X 2.4 in)
Weight: 425 g (15 oz) |
| ICL
Catalog Number: |
Description |
| HI 91531K/HI 766F |
Hi Temp Thermocouple readout and
flexible sheath high temp sensor |
| HI 91531K/HI 766F-C |
Hi Temp Thermocouple readout and flexible
sheath high temp sensor.
Supplied with NIST traceable, ISO/IEC 17025 accredited report of
calibration. |
|